SAE AIR4964

Exposure Levels of UV Radiation in Nondestructive Inspection Processes.

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$29.92 tax incl.

$68.00 tax incl.

(price reduced by 56 %)

1000 items in stock

Standard:
  • AIR4964
Reaffirmed:
  • 2007-02-16
Issued:
  • 1998-03-01
Issuing:
  • Ams K Non Destructive Methods And Processes Committee
Scope:

Long wave ultraviolet or UV-A radiation (between 320 59 400nm) is used for fluorescent inspections in magnetic particle and liquid penetrant examinations. The UV-A radiationn is obtained from either fluorescent or high intensity discharge lamps that are stationary or portable. The commercially available UV-A lamps possess a large variation in intensity output that can cause a legitimate concern for possible health hazard. This draft reviews the nature of UV-A radiation emitted by these lights, blacklight equipment, acceptable UV dosage limits adopted by the American Conference of Governmental Industrial Hygienists (ACGIH) and European Standards Committee for Nondestructive Testing, and recommendation of proper practices when working with UV-A radiation.

History:
StandardPublishedRevisionStatus
AIR49641998-03-01LatestReaffirmed
AKA:
  • SAE AIR 4964
Sector:
  • Aerospace
Topic:
  • Non-destructive tests

Contact us